Vesf7c 1/5HP Embraco / Nidec Variable Speed Compressors

Product Details
After-sales Service: by Nidec Embraco
Warranty: 18 Months
Lubrication Style: Lubricated
Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
11
Year of Establishment
2012-07-18
Find Similar Products

Basic Info.

Model NO.
VESF7C
Cooling System
Air Cooling
Cylinder Arrangement
Single Cylinder
Cylinder Position
Horizontal
Structure Type
Closed Type
Compress Level
Single-Stage
Refrigerant Type
R-600A
Voltage
230V
Frequency
32-150Hz
Transport Package
by Negotiation
Specification
7.23 cc
Trademark
Embraco
Origin
China
HS Code
84143011
Production Capacity
10000

Product Description

COMPRESSOR DEFINITION
Designation VES F7C
Nominal Voltage/Frequency 230 V 32-150 Hz
Engineering Number 513907073
A - APPLICATION / LIMIT WORKING CONDITIONS
1 Type Hermetic reciprocating compressor
2 Refrigerant R-600a
3 Nominal voltage and frequency 230 / 32-150 [ V / Hz ]
4 Application type Low-Medium Back Pressure (Fullmotion Compressors)
4.1 Evaporating temperature range -35°C to 0°C (-31°F to 32°F)
5 Motor type BPM
6 Starting torque LST - Low Starting Torque
7 Expantion device Capillary tube
8 Compressor cooling Operating voltage range
50 Hz 60 Hz
8.1 LBP (32ºC Ambient temperature) Static 160 to 264 V 160 to 264 V
8.2 LBP (43ºC Ambient temperature) Static 160 to 264 V 160 to 264 V
8.3 HBP (32ºC Ambient temperature) - - -
8.4 HBP (43ºC Ambient temperature) - - -
9 Maximum condensing temperature
9.1 Operating (gauge) 6.9 [kgf/cm²] (98 psig) / ºC - ºF
9.2 Peak (gauge) 7.8 [kgf/cm²] (111 psig) / ºC - ºF
10 Maximum winding temperature 130 [ °C ]
B - MECHANICAL DATA
1 Commercial designation 1/5 [hp]
2 Displacement 7.23 [cm³] (0.441 cu.in)
2.1 Bore [mm] 24.000
2.2 Stroke [mm] 16.000
3 Lubricant charge 205 [ml] (6.93 fl.oz.)
3.1 Lubricants approved
3.2 Lubricants type/viscosity ALQUILB / ISO5
4 Weight (with oil charge) 6.8 [kg] (14.99 lb.)
5 Nitrogen charge - [kgf/cm²]
C - ELETRICAL DATA
1 Nominal Voltage/Frequency/Number of Phases 230 V 31.7-150 Hz 3~ (Three phase)
2 Starting device type Inverter
2.1 Starting device VESF 2456 XXX X
3 Start capacitor - [µF(VAC minimum)]
4 Run capacitor - [µF(VAC minimum)]
5 Motor protection INVERTER VES 2456X
6 Start winding resistance 9.30 [Wat 25ºC (77ºF)] +/- 8%
7 Run winding resistance 9.30 [Wat 25ºC (77ºF)] +/- 8%
8 LRA - Locked rotor amperage (32/150 Hz) 2.10 [A] - Measured according to UL 984
9 FLA - Full load amperage L/MBP (32/150 Hz) - [A] - Measured according to UL 984
10
FLA - Full Load Amperage HBP (32/150 Hz) - [A] - Measured according to UL 984
11
Approval boards certification CCC - VDE
D - PERFORMANCE - CHECK POINT DATA
 
TEST CONDITIONS:                         ASHRAELBP32                      Evaporating temperature               -23.3°C (-9.94°F)
@220V950RPM                               Static                                     (Condensing temperature              54.4°C (129.92°F))
Cooling capacity
+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
119 30 35 19 0.19 0.37 6.20 1.56 1.82

TEST CONDITIONS:                         ASHRAELBP32                      Evaporating temperature               -23.3°C (-9.94°F)
@220V1300RPM                             Static                                     (Condensing temperature              54.4°C (129.92°F))
Cooling capacity
+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
171 43 50 27 0.24 0.54 6.45 1.63 1.89

TEST CONDITIONS:                         ASHRAELBP32                      Evaporating temperature               -23.3°C (-9.94°F)
@220V2000RPM                             Static                                     (Condensing temperature              54.4°C (129.92°F))
Cooling capacity
+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
270 68 79 41 0.34 0.85 6.57 1.66 1.93

TEST CONDITIONS:                         ASHRAELBP32                      Evaporating temperature               -23.3°C (-9.94°F)
@220V4000RPM                             Static                                     (Condensing temperature              54.4°C (129.92°F))
Cooling capacity
+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
536 135 157 84 0.65 1.68 6.35 1.60 1.86

E - PERFORMANCE - CURVES
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 35ºC (+95ºF) )
@220V950RPM                                  Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 68 17 20 12 0.16 0.21 5.60 1.41 1.64
-30 (-22) 99 25 29 14 0.17 0.31 6.90 1.74 2.02
-25 (-13) 136 34 40 17 0.18 0.43 8.21 2.07 2.41
-20 (- 4) 178 45 52 19 0.19 0.56 9.57 2.41 2.81
-15 (+ 5) 227 57 66 21 0.21 0.71 11.04 2.78 3.24
-10 (+14) 283 71 83 22 0.22 0.89 12.67 3.19 3.71
-5 (+23) 347 87 102 24 0.23 1.10 14.49 3.65 4.25
0 (+32) 420 106 123 25 0.24 1.33 16.56 4.17 4.85
 
E - PERFORMANCE - CURVES

 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 45ºC (+113ºF) )
@220V950RPM                                  Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 59 15 17 12 0.15 0.19 4.97 1.25 1.46
-30 (-22) 88 22 26 15 0.16 0.28 6.02 1.52 1.76
-25 (-13) 122 31 36 17 0.18 0.38 7.05 1.78 2.06
-20 (- 4) 163 41 48 20 0.20 0.51 8.11 2.04 2.37
-15 (+ 5) 211 53 62 23 0.22 0.66 9.24 2.33 2.71
-10 (+14) 267 67 78 25 0.24 0.84 10.50 2.65 3.08
-5 (+23) 332 84 97 28 0.26 1.05 11.94 3.01 3.50
0 (+32) 407 103 119 30 0.27 1.29 13.60 3.43 3.99
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 55ºC (+131ºF) )
@220V950RPM                                  Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 50 13 15 11 0.15 0.16 4.43 1.12 1.30
-30 (-22) 76 19 22 15 0.17 0.24 5.30 1.34 1.55
-25 (-13) 109 27 32 18 0.19 0.34 6.13 1.55 1.80
-20 (- 4) 149 37 44 21 0.21 0.47 6.96 1.75 2.04
-15 (+ 5) 196 49 58 25 0.24 0.62 7.85 1.98 2.30
-10 (+14) 253 64 74 28 0.27 0.80 8.83 2.23 2.59
-5 (+23) 319 80 93 32 0.29 1.01 9.96 2.51 2.92
0 (+32) 395 100 116 35 0.31 1.25 11.29 2.84 3.31
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 35ºC (+95ºF) )
@220V1300RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 102 26 30 16 0.18 0.32 6.19 1.56 1.81
-30 (-22) 144 36 42 19 0.20 0.45 7.33 1.85 2.15
-25 (-13) 191 48 56 23 0.22 0.60 8.47 2.13 2.48
-20 (- 4) 247 62 72 25 0.24 0.77 9.71 2.45 2.85
-15 (+ 5) 313 79 92 28 0.27 0.99 11.13 2.81 3.26
-10 (+14) 394 99 115 31 0.29 1.24 12.82 3.23 3.76
-5 (+23) 491 124 144 33 0.30 1.55 14.85 3.74 4.35
0 (+32) 608 153 178 35 0.31 1.93 17.31 4.36 5.07
 
E - PERFORMANCE - CURVES

 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 45ºC (+113ºF) )
@220V1300RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 84 21 24 17 0.18 0.26 5.06 1.28 1.48
-30 (-22) 124 31 36 20 0.20 0.39 6.10 1.54 1.79
-25 (-13) 170 43 50 24 0.22 0.53 7.10 1.79 2.08
-20 (- 4) 225 57 66 28 0.25 0.71 8.14 2.05 2.39
-15 (+ 5) 291 73 85 31 0.28 0.92 9.31 2.35 2.73
-10 (+14) 372 94 109 35 0.31 1.17 10.70 2.70 3.14
-5 (+23) 469 118 137 38 0.33 1.48 12.39 3.12 3.63
0 (+32) 586 148 172 41 0.34 1.86 14.46 3.64 4.24
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 55ºC (+131ºF) )
@220V1300RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 67 17 20 15 0.17 0.21 4.34 1.09 1.27
-30 (-22) 104 26 30 20 0.20 0.33 5.27 1.33 1.54
-25 (-13) 147 37 43 24 0.23 0.46 6.10 1.54 1.79
-20 (- 4) 199 50 58 29 0.26 0.62 6.94 1.75 2.03
-15 (+ 5) 262 66 77 33 0.29 0.83 7.85 1.98 2.30
-10 (+14) 340 86 100 38 0.32 1.07 8.93 2.25 2.62
-5 (+23) 435 110 128 42 0.35 1.38 10.26 2.59 3.01
0 (+32) 550 139 161 47 0.37 1.75 11.93 3.01 3.49
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 35ºC (+95ºF) )
@220V1600RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 126 32 37 21 0.21 0.39 6.03 1.52 1.77
-30 (-22) 174 44 51 24 0.24 0.55 7.15 1.80 2.09
-25 (-13) 232 59 68 28 0.26 0.73 8.32 2.10 2.44
-20 (- 4) 301 76 88 32 0.28 0.95 9.58 2.41 2.81
-15 (+ 5) 383 97 112 35 0.30 1.21 10.96 2.76 3.21
-10 (+14) 478 120 140 38 0.32 1.51 12.52 3.16 3.67
-5 (+23) 587 148 172 41 0.34 1.86 14.29 3.60 4.19
0 (+32) 712 179 209 43 0.36 2.26 16.31 4.11 4.78
 
E - PERFORMANCE - CURVES

 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 45ºC (+113ºF) )
@220V1600RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 102 26 30 21 0.21 0.32 4.98 1.25 1.46
-30 (-22) 152 38 45 25 0.24 0.48 6.08 1.53 1.78
-25 (-13) 212 53 62 29 0.27 0.67 7.17 1.81 2.10
-20 (- 4) 283 71 83 34 0.30 0.89 8.29 2.09 2.43
-15 (+ 5) 366 92 107 39 0.33 1.15 9.49 2.39 2.78
-10 (+14) 463 117 136 43 0.36 1.46 10.80 2.72 3.16
-5 (+23) 573 144 168 47 0.40 1.81 12.25 3.09 3.59
0 (+32) 699 176 205 50 0.43 2.22 13.90 3.50 4.07
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 55ºC (+131ºF) )
@220V1600RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 82 21 24 19 0.20 0.26 4.27 1.08 1.25
-30 (-22) 131 33 39 25 0.24 0.41 5.33 1.34 1.56
-25 (-13) 191 48 56 30 0.27 0.60 6.33 1.59 1.85
-20 (- 4) 261 66 76 36 0.31 0.82 7.30 1.84 2.14
-15 (+ 5) 343 86 100 41 0.35 1.08 8.28 2.09 2.43
-10 (+14) 438 110 128 47 0.39 1.38 9.31 2.35 2.73
-5 (+23) 547 138 160 52 0.43 1.73 10.44 2.63 3.06
0 (+32) 671 169 197 57 0.48 2.13 11.70 2.95 3.43
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 35ºC (+95ºF) )
@220V2000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 159 40 47 26 0.25 0.50 6.09 1.54 1.79
-30 (-22) 218 55 64 31 0.28 0.68 7.11 1.79 2.08
-25 (-13) 291 73 85 35 0.31 0.91 8.22 2.07 2.41
-20 (- 4) 380 96 111 40 0.35 1.19 9.48 2.39 2.78
-15 (+ 5) 487 123 143 45 0.38 1.53 10.91 2.75 3.20
-10 (+14) 615 155 180 49 0.41 1.94 12.57 3.17 3.68
-5 (+23) 765 193 224 53 0.43 2.42 14.48 3.65 4.24
0 (+32) 939 237 275 56 0.45 2.97 16.68 4.20 4.89
 
E - PERFORMANCE - CURVES

 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 45ºC (+113ºF) )
@220V2000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 139 35 41 26 0.24 0.44 5.31 1.34 1.56
-30 (-22) 197 50 58 32 0.28 0.62 6.23 1.57 1.83
-25 (-13) 268 67 78 37 0.32 0.84 7.18 1.81 2.10
-20 (- 4) 353 89 103 43 0.36 1.11 8.20 2.07 2.40
-15 (+ 5) 455 115 133 49 0.40 1.43 9.34 2.35 2.74
-10 (+14) 576 145 169 54 0.43 1.82 10.62 2.68 3.11
-5 (+23) 717 181 210 59 0.47 2.27 12.09 3.05 3.54
0 (+32) 881 222 258 64 0.50 2.79 13.79 3.47 4.04
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 55ºC (+131ºF) )
@220V2000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 112 28 33 25 0.24 0.35 4.48 1.13 1.31
-30 (-22) 172 43 51 32 0.28 0.54 5.43 1.37 1.59
-25 (-13) 244 62 72 38 0.33 0.77 6.35 1.60 1.86
-20 (- 4) 329 83 97 45 0.38 1.04 7.26 1.83 2.13
-15 (+ 5) 430 108 126 52 0.43 1.35 8.22 2.07 2.41
-10 (+14) 547 138 160 59 0.48 1.73 9.26 2.33 2.71
-5 (+23) 683 172 200 66 0.52 2.16 10.42 2.63 3.05
0 (+32) 841 212 246 72 0.56 2.67 11.73 2.96 3.44
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 35ºC (+95ºF) )
@220V3000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 231 58 68 39 0.33 0.72 5.85 1.47 1.71
-30 (-22) 321 81 94 47 0.39 1.01 6.77 1.71 1.98
-25 (-13) 434 109 127 56 0.44 1.36 7.81 1.97 2.29
-20 (- 4) 571 144 167 64 0.50 1.79 8.96 2.26 2.63
-15 (+ 5) 732 185 215 72 0.55 2.30 10.22 2.57 2.99
-10 (+14) 918 231 269 80 0.60 2.90 11.58 2.92 3.39
-5 (+23) 1130 285 331 86 0.65 3.57 13.03 3.28 3.82
0 (+32) 1366 344 400 92 0.69 4.33 14.57 3.67 4.27
 
E - PERFORMANCE - CURVES

 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 45ºC (+113ºF) )
@220V3000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 207 52 61 40 0.34 0.65 5.16 1.30 1.51
-30 (-22) 289 73 85 48 0.40 0.91 5.98 1.51 1.75
-25 (-13) 397 100 116 58 0.46 1.25 6.89 1.74 2.02
-20 (- 4) 531 134 156 67 0.52 1.67 7.89 1.99 2.31
-15 (+ 5) 690 174 202 77 0.59 2.17 8.97 2.26 2.63
-10 (+14) 877 221 257 87 0.65 2.77 10.13 2.55 2.97
-5 (+23) 1090 275 319 96 0.71 3.45 11.36 2.86 3.33
0 (+32) 1330 335 390 105 0.77 4.22 12.66 3.19 3.71
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 55ºC (+131ºF) )
@220V3000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 186 47 55 40 0.35 0.58 4.66 1.17 1.36
-30 (-22) 262 66 77 49 0.41 0.82 5.41 1.36 1.59
-25 (-13) 366 92 107 59 0.48 1.15 6.23 1.57 1.83
-20 (- 4) 497 125 146 70 0.55 1.56 7.12 1.79 2.09
-15 (+ 5) 655 165 192 81 0.62 2.06 8.06 2.03 2.36
-10 (+14) 842 212 247 93 0.70 2.66 9.06 2.28 2.66
-5 (+23) 1058 267 310 105 0.78 3.35 10.11 2.55 2.96
0 (+32) 1303 328 382 116 0.86 4.13 11.19 2.82 3.28
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 35ºC (+95ºF) )
@220V4000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 301 76 88 54 0.44 0.94 5.58 1.41 1.63
-30 (-22) 409 103 120 64 0.51 1.28 6.41 1.61 1.88
-25 (-13) 545 137 160 74 0.58 1.71 7.33 1.85 2.15
-20 (- 4) 713 180 209 85 0.65 2.24 8.37 2.11 2.45
-15 (+ 5) 917 231 269 96 0.73 2.89 9.54 2.40 2.79
-10 (+14) 1159 292 339 107 0.80 3.65 10.85 2.73 3.18
-5 (+23) 1442 363 422 117 0.87 4.56 12.33 3.11 3.61
0 (+32) 1770 446 519 127 0.93 5.61 13.98 3.52 4.10


E - PERFORMANCE - CURVES
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 45ºC (+113ºF) )
@220V4000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 286 72 84 56 0.45 0.89 5.09 1.28 1.49
-30 (-22) 390 98 114 67 0.52 1.22 5.85 1.47 1.71
-25 (-13) 519 131 152 78 0.60 1.63 6.68 1.68 1.96
-20 (- 4) 677 171 198 89 0.68 2.13 7.58 1.91 2.22
-15 (+ 5) 868 219 254 101 0.76 2.73 8.59 2.16 2.52
-10 (+14) 1093 275 320 112 0.84 3.45 9.71 2.45 2.84
-5 (+23) 1357 342 398 124 0.92 4.29 10.96 2.76 3.21
0 (+32) 1662 419 487 134 0.99 5.27 12.36 3.12 3.62
 
TEST CONDITIONS:                            ASHRAE32                                        (Condensing temperature 55ºC (+131ºF) )
@220V4000RPM                                Static
Evaporating temperature Cooling capacity

+/- 5%
Power consumption
+/- 5%
Current consumption
+/- 5%
Gas flow rate
+/- 5%
EFFICIENCY RATE

+/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 256 64 75 56 0.44 0.80 4.52 1.14 1.32
-30 (-22) 358 90 105 68 0.52 1.12 5.25 1.32 1.54
-25 (-13) 483 122 142 80 0.61 1.52 6.01 1.51 1.76
-20 (- 4) 633 160 186 93 0.70 1.99 6.82 1.72 2.00
-15 (+ 5) 813 205 238 106 0.80 2.56 7.70 1.94 2.26
-10 (+14) 1024 258 300 118 0.89 3.23 8.67 2.18 2.54
-5 (+23) 1270 320 372 130 0.98 4.02 9.74 2.45 2.85
0 (+32) 1555 392 456 142 1.06 4.93 10.92 2.75 3.20